    Seika's measurement technique enables a linear relationship between the angle to be measured and the output signal. The determined angle is independent of local gravitational acceleration.
This means that no matter where the measurement is being taken, whether it is in Europe, Australia, on Mount Everest or on the moon, the inclination will be measured correctly.
 
Inclinometers
    Accessories Go Back to Inclinometers Products

 
     
 
 

N2, N3 & N4

 
 
 

N2, N3 & N4

• Linear output.

  N2 N3 N4  
• High measurement accuracy. • Measuring Range: ±10° ±30° ±70°  
• High long term stability. • Resolution: 0.002° 0.005° 0.01°
• Minimal zero point drift. • Linearity: 0.2%    
• Small housing. • Transverse sensitivity: <1% at 30° tilt
• Zero hystersis. • Settling Time: <0.3 seconds
    • Hermetically sealed.      
• Shockproof.      
 
 
 
 
     
 
 

NA2-05, NA2-10, NA3-30, NA4-45 & NA4-70

 
 
 

NA2-05, NA2-10, NA3-30, NA4-45 & NA4-70

• Temperature compensated

  NA2-05 NA2-10    
output. • Measuring Range: ±5° ±10°    
• Hystersis free output. • Resolution: <0.001° <0.002°  
• Light weight. • Nominal sensitivity: 400mV/° 200mV/°    
• Low non-linearity. • Linearity: 0.02° 0.03°  
• Low power consumption.        
    • Hermetically sealed.   NA3-30 NA4-45 NA4-70
• High long term stability. • Measuring Range: ±30° ±45° ±70°
  • Resolution: <0.005° <0.01° <0.01°
  • Nominal sensitivity: 66.6mV/° 44.4mV/° 28.57mV/°
  • Linearity: 0.06° 0.14° 0.28°
 
 
 
 
     
 
 

NB3

 
 
 

NB3

• linear output characteristics

  NB3    
• High measurement accuracy. • Measuring Range: ± 10 degrees    
• high long-term stability • Resolution: <0.001 degrees  
• hysteresis free output signal • Linearity: <0.2% F.S.    
• minimal zero point drift • Display range: ± 20 degrees  
• integrated sensor electronics • Sensitivity approx. 17mV/degree                    
    • low power consumption • Settling Time: <0.3 seconds  
       
 
 
 
 
     
 
 

NG2, NG3 & NG4

 
 
 

NG2, NG3 & NG4

• +5vDC supply.

  NG2 NG3 NG4  
• Non-conditioned output. • Measuring Range: ±10° ±30° ±80°  
• High long term stability. • Resolution: 0.001° 0.003° 0.01°
• Minimal zero point drift. • Linearity: 0.1%      
• Small housing. • Transverse  
• Zero hystersis. sensitivity: <0.5% at 45° tilt    
    • Hermetically sealed. • Settling Time: <0.3 seconds    

• Shockproof.

       
 
 
 
 
     
 
 

NG2I, NG3I & NG4I - Loop powered inclinometer

 
 
 

NG2I, NG3I & NG4I - Loop powered inclinometer

• 4 to 20mA.

  NGI2 NGI3 NGI4  
• 2 wire connection. • Measuring Range: ±10° ±30° ±80°  
• High long term stability. • Resolution: 0.001° 0.003° 0.01°
• Minimal zero point drift. • Sensitivity: 0.1% 0.266mA/° 0.1mA/°  
• Small housing. • Linearity: <1.10-3F.S.
• Zero hystersis. • Transverse      
    • IP65. sensitivity: <0.5% at 45° tilt    
• Shockproof. • Settling Time: <0.3 seconds    
 
 
 
 
     
 
 

NG2U, NG3U & NG4U

 
 
 

NG2U, NG3U & NG4U

• 9 to 30vDC unregulated.

  NGU2 NGU3 NGU4  
• 0-5vDC output. • Measuring Range: ±10° ±30° ±80°  
• Temperature compensated. • Resolution: 0.001° 0.003° 0.01°
• Minimal zero point drift. • Sensitivity: 200mV/° 66.67mV/° 25mV/°  
• Small housing. • Linearity: 1.10-3%
• Zero hystersis. • Transverse      
    • IP65. sensitivity: <0.5% at 45° tilt    
• Shockproof. • Settling Time: <0.3 seconds    
 
 
 
 
     
 
 

NG360

 
 
 

NG360

• 360 degree.

  NG360      
• RS-485 output • Measuring Range: 360° Up to 78 sensors can be operated using a single communications line.  
• 9 to 15vDC supply. • Resolution: 0.01°
• 16bit. • Linearity: ±0.25°  
• Small housing. • Transverse  
• Zero hystersis. sensitivity: <0.5% at 45° tilt
    • IP65. • Settling Time: <0.3 seconds
• Shockproof.    
 
 
 
 
     
  Go to Accelerometers Go to Sensor Boxes Go Back to Inclinometers Products