• Linear output.
|
|
N2 |
N3 |
N4 |
|
| • High measurement accuracy. |
• Measuring Range: |
±10° |
±30° |
±70° |
|
| • High long term stability. |
• Resolution: |
0.002° |
0.005° |
0.01° |
| • Minimal zero point drift. |
• Linearity: |
0.2% |
|
|
| • Small housing. |
• Transverse sensitivity: |
<1% at 30° tilt |
 |
| • Zero hystersis. |
• Settling Time: |
<0.3 seconds |
| |
|
• Hermetically sealed. |
|
|
|
 |
| • Shockproof. |
|
|
|
|
|
| |
|
|
| |
|
|
| |
| |
NA2-05, NA2-10, NA3-30, NA4-45 & NA4-70 |
|
|
| |
| |

|
• Temperature compensated |
|
NA2-05 |
NA2-10 |
|
|
| • output. |
• Measuring Range: |
±5° |
±10° |
|
|
| • Hystersis free output. |
• Resolution: |
<0.001° |
<0.002° |
|
| • Light weight. |
• Nominal sensitivity: |
400mV/° |
200mV/° |
|
|
| • Low non-linearity. |
• Linearity: |
0.02° |
0.03° |
|
 |
| • Low power consumption. |
|
|
|
|
| |
|
• Hermetically sealed. |
|
NA3-30 |
NA4-45 |
NA4-70 |
 |
| • High long term stability. |
• Measuring Range: |
±30° |
±45° |
±70° |
| |
• Resolution: |
<0.005° |
<0.01° |
<0.01° |
| |
• Nominal sensitivity: |
66.6mV/° |
44.4mV/° |
28.57mV/° |
| |
• Linearity: |
0.06° |
0.14° |
0.28° |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
| |

|
• linear output characteristics |
|
NB3 |
|
|
| • High measurement accuracy. |
• Measuring Range: |
± 10 degrees |
|
|
| • high long-term stability |
• Resolution: |
<0.001 degrees |
|
| • hysteresis free output signal |
• Linearity: |
<0.2% F.S. |
|
|
| • minimal zero point drift |
• Display range: |
± 20 degrees |
|
 |
| • integrated sensor electronics |
• Sensitivity |
approx. 17mV/degree |
|
| |
|
• low power consumption |
• Settling Time: |
<0.3 seconds |
|
 |
| |
|
|
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
| |

|
• +5vDC supply. |
|
NG2 |
NG3 |
NG4 |
|
| • Non-conditioned output. |
• Measuring Range: |
±10° |
±30° |
±80° |
|
| • High long term stability. |
• Resolution: |
0.001° |
0.003° |
0.01° |
| • Minimal zero point drift. |
• Linearity: |
0.1% |
|
|
|
| • Small housing. |
• Transverse |
|
 |
| • Zero hystersis. |
• sensitivity: |
<0.5% at 45° tilt |
|
|
| |
|
• Hermetically sealed. |
• Settling Time: |
<0.3 seconds |
|
|
 |
• Shockproof.
|
|
|
|
|
|
|
| |
|
|
| |
|
|
| |
| |
NG2I, NG3I & NG4I - Loop powered inclinometer |
|
|
| |
| |

|
• 4 to 20mA. |
|
NGI2 |
NGI3 |
NGI4 |
|
| • 2 wire connection. |
• Measuring Range: |
±10° |
±30° |
±80° |
|
| • High long term stability. |
• Resolution: |
0.001° |
0.003° |
0.01° |
| • Minimal zero point drift. |
• Sensitivity: |
0.1% |
0.266mA/° |
0.1mA/° |
|
| • Small housing. |
• Linearity: |
<1.10-3F.S. |
 |
| • Zero hystersis. |
• Transverse |
|
|
|
| |
|
• IP65. |
• sensitivity: |
<0.5% at 45° tilt |
|
|
 |
| • Shockproof. |
• Settling Time: |
<0.3 seconds |
|
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
| |

|
• 9 to 30vDC unregulated. |
|
NGU2 |
NGU3 |
NGU4 |
|
| • 0-5vDC output. |
• Measuring Range: |
±10° |
±30° |
±80° |
|
| • Temperature compensated. |
• Resolution: |
0.001° |
0.003° |
0.01° |
| • Minimal zero point drift. |
• Sensitivity: |
200mV/° |
66.67mV/° |
25mV/° |
|
| • Small housing. |
• Linearity: |
1.10-3% |
 |
| • Zero hystersis. |
• Transverse |
|
|
|
| |
|
• IP65. |
• sensitivity: |
<0.5% at 45° tilt |
|
|
 |
| • Shockproof. |
• Settling Time: |
<0.3 seconds |
|
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
| |

|
• 360 degree. |
|
NG360 |
|
|
|
| • RS-485 output |
• Measuring Range: |
360° |
Up to 78 sensors can be operated using a single communications line. |
|
| • 9 to 15vDC supply. |
• Resolution: |
0.01° |
| • 16bit. |
• Linearity: |
±0.25° |
|
| • Small housing. |
• Transverse |
|
 |
| • Zero hystersis. |
• sensitivity: |
<0.5% at 45° tilt |
| |
|
• IP65. |
• Settling Time: |
<0.3 seconds |
 |
| • Shockproof. |
|
|
|
|
| |
|
|
| |
|
|
| |
Go to Accelerometers |
Go to Sensor Boxes |
Go Back to Inclinometers Products |
|
| |
|
|
| |